Non-Destructive Testing (NDT) methods performed at Danville Metal include Fluorescent Penetrant Inspection (FPI) and Computed Radiography/Digital X-Ray inspection. Our NDT inspectors are held to rigid standards for acceptance criteria and training, and our in-house Level III inspector oversees development of NDT techniques, interprets customer specifications, monitors compliance, and trains our Level II inspectors.
Fluorescent Penetrant Inspection
Our penetrant inspection process utilizes Magnaflux ZL-67 for high sensitivity results.
Computed Radiography/Digital X-Ray
Danville Metal uses the state-of-the-art Fuji Dynamix Series IV CR Scanner for computed radiography/digital X-ray. This provides timely analysis of welds for both setup and production.
Our NDT processes have been Nadcap accredited for over 20 years.
Radiography: Comet 225 kV Fuji Dynamix Series IV CR Scanner
Fluorescent Penetrant: Magnaflux ZL-67 Fluorescent Penetrant with ZP-4 Dry Developer
Pressure Test: Mediums: Air, Water, and Oil